But it can be a real challenge to record clean signals, especially when performing a lead ECG. There are numerous elements to get right: the data recording equipment needs to be set up correctly, the subject needs to be comfortable, and you need to position the surface electrodes on the subject's torso and limbs precisely in order to get results that you can interpret accurately. Before placing your electrodes, it is very important to prepare the subject's skin by wiping the chest area thoroughly with skin cleansing alcohol swabs.
It is especially important to correctly place V1 and V2 because the remaining chest leads are placed in relation to these. To determine the placement of V1 and V2, feel to identify the top of your subject's sternum. Approximately 4 centimeters below this, there is a ridge. This identifies the second intercostal space. Feeling down, you will come across the third and fourth intercostal spaces.
Use a skin-safe marker to mark the fourth intercostal space as V2. V4 can be found one intercostal space lower than V2, in line with the middle of the clavicle.
Mark V4 with your skin safe marker. Next, track along the torso to the subject's left to find V6 at mid auxiliary on the same level as V4. Mark V6. The 6 electrode wires can now be connected to your recording device. Apply lead 1 to the left arm. We suggest the front of the left shoulder in a place where there is little muscle or muscle movement, to avoid any EMG signal disturbance.
Next, apply lead 2 to the right arm. Again, the front of the shoulder is suggested here, in a place with little or no muscle or movement. Then connect the left leg. Place the electrode slightly above the ankle.
This electrode is the reference for all of the augmented leads. Finally, apply the "common" on the right-hand side ankle. This connects to the ground input on your recording device Octal Bio Amp. To see a short video and guide on the end to end process of setting up equipment and recording signals for a lead ECG using the Octal Bio Amp and Cardiac Axis calculator from ADInstruments, please click through here.
Bio Amps interface seamlessly with PowerLab for high-quality signal acquisition, with data flowing directly into LabChart for analysis, with specialized features and modules including the ECG Analysis Add-On and Heart Rate Variability Add-On designed for the analysis of signals from humans.
From the sinus node, the electrical impulse starts by spreading throughout the atria from right to left. When this happens, the cells lose their internal negativity, a process known as depolarization. The depolarization of the atria causes them to contract.
The electrical current then spreads to the atrioventricular node AV node , from where it is further transmitted to the intraventricular Septum separates the left and right ventricles. In order to depolarize the ventricles, the electrical impulse travels through the bundle of His, along the right and left bundle branches from left to right , and ends at the Purkinje fibers.
This process causes depolarization of the ventricles, causing them to contract. While the ventricles are being depolarized, the atria are regaining their internal electrical negativity, a process known as repolarization. This allows them to relax. Once the ventricles have fully depolarized, they too become repolarized, and which point they relax as well.
The entire process of depolarization and repolarization is depicted on the ECG. The individual events are represented as spikes and waves, each representing a specific part of the cardiac conduction cycle. The picture below shows the pathway of an electrical impulse as it corresponds to the spikes and waves on an ECG. To do this, the heart is shown on its side. Stuttgart, 6. Auflage , S. The P wave represents the depolarization contraction of the atria, the PR segment the transmission of the electrical impulse to the ventricles, the QRS complex represents depolarization contraction of the ventricles and the T wave shows the repolarization relaxation of the ventricles.
When disturbances of the conduction system are present, this can be detected via abnormalities of the spikes and waves on an ECG. An electrocardiogram uses electrodes attached to the skin , which are able to detect electrical currents, in order to provide us with information about the heart. The information detected by the electrodes is used to calculate measurements, known as leads.
A standard ECG includes 12 leads, i. Each lead provides us with information about different parts of the heart. A standard ECG typically requires 10 electrodes in order to provide a lead view. Circulation problems of the coronary arteries can also be detected, which can help to diagnose a heart attack. During a resting ECG the body must be relaxed at rest , as the neighboring muscles and nerves also produce electrical tension. The electrodes are attached to predetermined locations on the body, located on the chest, arms and legs, which are connected to the ECG machine via a cable.
The electrodes can detect electrical tension of less than a millivolt, which is then transcribed onto graph paper to produce an ECG. An exercise ECG or stress ECG is performed under physical stress, as some changes are only detected when the heart is strained.